deutsch deutsch
HKW-Elektronik
Products

Engineering parameters microcontroller modul MCM DCF - MCM DCF

The MCM module decodes the DCF time signal andputs out the checkedtime and date information to an RSR232 compatible interface.

A special command set (s. datasheet) was developed for the communication between the module and a host computer. To save power the MCM module is able to control the time code receiver unit by the PON pin.

Technical characteristics: (Test conditions: VDD=3,0V ; VSS=0V; ( + for current into the module))

Parameters

Symbol

min

typ

max

Unit

Power consumtion

-normal mode

-receive mode

IDD

15

0,5

20

0,7

50

1,0

µA

mA

Power supply

VDD

2,4

3,0

3,6

V

Input voltage high

VIH

0,8VDD

VDD

V

Input voltage low

VIL

VSS

0,2VDD

V

Input voltage high

IIH

20

300

nA

Output voltage hig (VOH=2,4V)

IOH

0,8

1,3

mA

Output voltage low (VOL=0,6V)

IOL

1,5

2,4

mA

Input voltage low *

IIL

-0,8

-1,6

-3

µA

Input voltage low **

IIL

-6

-13

-20

µA

Input voltage low (für X2)

IIL

-12

-24

-40

µA

Operation temperature range

TA

-10

60

0C

Camp temperature

TL

-40

85

0C

*for connector pads: X4, X5, X6