A special command set (s. datasheet) was developed for the communication between the module and a host computer. To save power the MCM module is able to control the time code receiver unit by the PON pin.
Technical characteristics: (Test conditions: VDD=3,0V ; VSS=0V; ( + for current into the module))
min typ max Unit Power consumtion -normal mode -receive mode IDD 15 0,5 20 0,7 50 1,0 µA mA Power supply VDD 2,4 3,0 3,6 V Input voltage high VIH 0,8VDD VDD V Input voltage low VIL VSS 0,2VDD V Input voltage high IIH 20 300 nA Output voltage hig (VOH=2,4V) IOH 0,8 1,3 mA Output voltage low (VOL=0,6V) IOL 1,5 2,4 mA Input voltage low * IIL -0,8 -1,6 -3 µA Input voltage low ** IIL -6 -13 -20 µA Input voltage low (für X2) IIL -12 -24 -40 µA Operation temperature range TA -40 85 0C Camp temperature TL -40 85 0C
Parameters
Symbol
*for connector pads: X4, X5, X6
** for connector pads: X4, X5, X6, X8